<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gyron &#187; cooling</title>
	<atom:link href="http://blog.gyron.net/tag/cooling/feed/" rel="self" type="application/rss+xml" />
	<link>http://blog.gyron.net</link>
	<description>Specialist datacentre service provider</description>
	<lastBuildDate>Mon, 25 Jul 2011 07:48:29 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1.2</generator>
		<item>
		<title>Centro Suite 1 Phase 2 fit-out update</title>
		<link>http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/</link>
		<comments>http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/#comments</comments>
		<pubDate>Tue, 11 May 2010 16:56:38 +0000</pubDate>
		<dc:creator>Robin Balen - Gyron</dc:creator>
				<category><![CDATA[Centro fit-out]]></category>
		<category><![CDATA[Pictures]]></category>
		<category><![CDATA[batteries]]></category>
		<category><![CDATA[caging]]></category>
		<category><![CDATA[centro]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[crac]]></category>
		<category><![CDATA[deliveries]]></category>
		<category><![CDATA[expansion]]></category>
		<category><![CDATA[fit out]]></category>
		<category><![CDATA[power]]></category>
		<category><![CDATA[UPS]]></category>

		<guid isPermaLink="false">http://blog.gyron.net/?p=628</guid>
		<description><![CDATA[Followers of our Twitter feed have been enjoying some behind the scenes photos from the expansion works at our Centro facility. We&#8217;ve put together a quick post here with some highlights: Related PostsCentro update &#8211; Chiller and transformer basesGyron unveils new 8MW &#8220;Maylands&#8221; datacentre in Hemel Hempstead, UKCentro update &#8211; Final commissioning works]]></description>
			<content:encoded><![CDATA[<p>Followers of our <a href="http://twitter.com/gyron">Twitter feed</a> have been enjoying some behind the scenes photos from the <a href="http://blog.gyron.net/press-releases/gyron-celebrates-10th-birthday-with-record-contract-wins-and-continued-expansion-at-centro-datacentre/">expansion works</a> at our Centro facility. We&#8217;ve put together a quick post here with some highlights:</p>

<a href='http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/attachment/x2_14fc6ed/' title='Bases ready for installation of additional 5 air conditioning units'><img width="150" height="150" src="http://blog.gyron.net/wp-content/uploads/x2_14fc6ed-150x150.jpg" class="attachment-thumbnail" alt="Bases ready for installation of additional 5 air conditioning units" title="Bases ready for installation of additional 5 air conditioning units" /></a>
<a href='http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/attachment/x2_1252eef/' title='Installation of new ultra-secure dedicated caged area'><img width="150" height="150" src="http://blog.gyron.net/wp-content/uploads/x2_1252eef-150x150.jpg" class="attachment-thumbnail" alt="Installation of new ultra-secure dedicated caged area" title="Installation of new ultra-secure dedicated caged area" /></a>
<a href='http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/attachment/x2_10ea32b/' title='Additional 250kW Carrier chiller arrives on-site'><img width="150" height="150" src="http://blog.gyron.net/wp-content/uploads/x2_10ea32b-150x150.jpg" class="attachment-thumbnail" alt="Additional 250kW Carrier chiller arrives on-site" title="Additional 250kW Carrier chiller arrives on-site" /></a>
<a href='http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/attachment/x2_140d308/' title='Delivery of new 2,500L chiller water buffer tank'><img width="150" height="150" src="http://blog.gyron.net/wp-content/uploads/x2_140d308-150x150.jpg" class="attachment-thumbnail" alt="Delivery of new 2,500L chiller water buffer tank" title="Delivery of new 2,500L chiller water buffer tank" /></a>
<a href='http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/attachment/x2_13676ca/' title='Delivery of UPS batteries to support 400kW at 2N redundancy'><img width="150" height="150" src="http://blog.gyron.net/wp-content/uploads/x2_13676ca-150x150.jpg" class="attachment-thumbnail" alt="Delivery of UPS batteries to support 400kW at 2N redundancy" title="Delivery of UPS batteries to support 400kW at 2N redundancy" /></a>
<a href='http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/attachment/x2_136ecee/' title='UPS battery build nearing completion'><img width="150" height="150" src="http://blog.gyron.net/wp-content/uploads/x2_136ecee-150x150.jpg" class="attachment-thumbnail" alt="UPS battery build nearing completion" title="UPS battery build nearing completion" /></a>

<h3  class="related_post_title">Related Posts</h3><ul class="related_post"><li><a href="http://blog.gyron.net/pictures/centro-update-chiller-and-transformer-bases/" title="Centro update &#8211; Chiller and transformer bases">Centro update &#8211; Chiller and transformer bases</a></li><li><a href="http://blog.gyron.net/press-releases/gyron-unveils-new-8mw-maylands-datacentre-in-hemel-hempstead-uk/" title="Gyron unveils new 8MW &#8220;Maylands&#8221; datacentre in Hemel Hempstead, UK">Gyron unveils new 8MW &#8220;Maylands&#8221; datacentre in Hemel Hempstead, UK</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-final-commissioning-works/" title="Centro update &#8211; Final commissioning works">Centro update &#8211; Final commissioning works</a></li></ul>]]></content:encoded>
			<wfw:commentRss>http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Centro update &#8211; Final air conditioning works</title>
		<link>http://blog.gyron.net/pictures/centro-update-final-air-conditioning-works/</link>
		<comments>http://blog.gyron.net/pictures/centro-update-final-air-conditioning-works/#comments</comments>
		<pubDate>Wed, 27 May 2009 11:07:40 +0000</pubDate>
		<dc:creator>Robin Balen - Gyron</dc:creator>
				<category><![CDATA[Centro fit-out]]></category>
		<category><![CDATA[Pictures]]></category>
		<category><![CDATA[air conditioning]]></category>
		<category><![CDATA[centro]]></category>
		<category><![CDATA[commissioning]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[lagging]]></category>

		<guid isPermaLink="false">http://blog.gyron.net/?p=462</guid>
		<description><![CDATA[Related PostsCentro update &#8211; HV transformer installation and chiller pipework connectionsCentro update &#8211; ChillersCentro update &#8211; Air conditioning pump installation]]></description>
			<content:encoded><![CDATA[<div id="attachment_466" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8168.jpg" rel="lightbox[462]"><img class="size-medium wp-image-466" title="Finalising lagging for the chilled water pipework" src="http://blog.gyron.net/wp-content/uploads/5d-img_8168-480x320.jpg" alt="Finalising lagging for the chilled water pipework" width="480" height="320" /></a><p class="wp-caption-text">Finalising lagging for the chilled water pipework</p></div>
<div id="attachment_465" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8165.jpg" rel="lightbox[462]"><img class="size-medium wp-image-465" title="Setting flow rates for the chilled water valves" src="http://blog.gyron.net/wp-content/uploads/5d-img_8165-480x320.jpg" alt="Setting flow rates for the chilled water valves" width="480" height="320" /></a><p class="wp-caption-text">Setting flow rates for the chilled water valves</p></div>
<div id="attachment_464" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8160.jpg" rel="lightbox[462]"><img class="size-medium wp-image-464" title="Commissioning the air conditioning chillers" src="http://blog.gyron.net/wp-content/uploads/5d-img_8160-480x320.jpg" alt="Commissioning the air conditioning chillers" width="480" height="320" /></a><p class="wp-caption-text">Commissioning the air conditioning chillers</p></div>
<h3  class="related_post_title">Related Posts</h3><ul class="related_post"><li><a href="http://blog.gyron.net/pictures/centro-update-hv-transformer-installation-and-chiller-pipework-connections/" title="Centro update &#8211; HV transformer installation and chiller pipework connections">Centro update &#8211; HV transformer installation and chiller pipework connections</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-chillers/" title="Centro update &#8211; Chillers">Centro update &#8211; Chillers</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-air-conditioning-pump-installation/" title="Centro update &#8211; Air conditioning pump installation">Centro update &#8211; Air conditioning pump installation</a></li></ul>]]></content:encoded>
			<wfw:commentRss>http://blog.gyron.net/pictures/centro-update-final-air-conditioning-works/feed/</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>Centro update &#8211; HV transformer installation and chiller pipework connections</title>
		<link>http://blog.gyron.net/pictures/centro-update-hv-transformer-installation-and-chiller-pipework-connections/</link>
		<comments>http://blog.gyron.net/pictures/centro-update-hv-transformer-installation-and-chiller-pipework-connections/#comments</comments>
		<pubDate>Fri, 08 May 2009 08:34:31 +0000</pubDate>
		<dc:creator>Robin Balen - Gyron</dc:creator>
				<category><![CDATA[Centro fit-out]]></category>
		<category><![CDATA[Pictures]]></category>
		<category><![CDATA[air conditioning]]></category>
		<category><![CDATA[centro]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[HV]]></category>
		<category><![CDATA[LV]]></category>
		<category><![CDATA[power]]></category>
		<category><![CDATA[substation]]></category>
		<category><![CDATA[switchgear]]></category>
		<category><![CDATA[transformer]]></category>

		<guid isPermaLink="false">http://blog.gyron.net/?p=454</guid>
		<description><![CDATA[Related PostsCentro update &#8211; Chiller and transformer basesCentro update &#8211; HV switchgear connectionsCentro update &#8211; HV switchgear delivery and installation]]></description>
			<content:encoded><![CDATA[<div id="attachment_455" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8074.jpg" rel="lightbox[454]"><img class="size-medium wp-image-455" title="3MVA HV transformer installed within secure compound" src="http://blog.gyron.net/wp-content/uploads/5d-img_8074-480x320.jpg" alt="3MVA HV transformer installed within secure compound" width="480" height="320" /></a><p class="wp-caption-text">3MVA HV transformer installed within secure compound</p></div>
<div id="attachment_456" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8084.jpg" rel="lightbox[454]"><img class="size-medium wp-image-456" title="HV feed from our dedicated substation being terminated" src="http://blog.gyron.net/wp-content/uploads/5d-img_8084-480x320.jpg" alt="HV feed from our dedicated substation being terminated" width="480" height="320" /></a><p class="wp-caption-text">HV feed from our dedicated substation being terminated</p></div>
<div id="attachment_459" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8101.jpg" rel="lightbox[454]"><img class="size-medium wp-image-459" title="First of 24 LV cables connecting the transformer and switchgear panels" src="http://blog.gyron.net/wp-content/uploads/5d-img_8101-480x321.jpg" alt="First of 24 LV cables connecting the transformer and switchgear panels" width="480" height="321" /></a><p class="wp-caption-text">First of 24 LV cables connecting the transformer and switchgear panels</p></div>
<div id="attachment_457" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8086.jpg" rel="lightbox[454]"><img class="size-medium wp-image-457" title="Final connections being made on chilled water pipework" src="http://blog.gyron.net/wp-content/uploads/5d-img_8086-480x320.jpg" alt="Final connections being made on chilled water pipework" width="480" height="320" /></a><p class="wp-caption-text">Final connections being made on chilled water pipework</p></div>
<h3  class="related_post_title">Related Posts</h3><ul class="related_post"><li><a href="http://blog.gyron.net/pictures/centro-update-chiller-and-transformer-bases/" title="Centro update &#8211; Chiller and transformer bases">Centro update &#8211; Chiller and transformer bases</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-hv-switchgear-connections/" title="Centro update &#8211; HV switchgear connections">Centro update &#8211; HV switchgear connections</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-hv-switchgear-delivery-and-installation/" title="Centro update &#8211; HV switchgear delivery and installation">Centro update &#8211; HV switchgear delivery and installation</a></li></ul>]]></content:encoded>
			<wfw:commentRss>http://blog.gyron.net/pictures/centro-update-hv-transformer-installation-and-chiller-pipework-connections/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Centro update &#8211; Chillers</title>
		<link>http://blog.gyron.net/pictures/centro-update-chillers/</link>
		<comments>http://blog.gyron.net/pictures/centro-update-chillers/#comments</comments>
		<pubDate>Tue, 28 Apr 2009 19:29:16 +0000</pubDate>
		<dc:creator>Robin Balen - Gyron</dc:creator>
				<category><![CDATA[Centro fit-out]]></category>
		<category><![CDATA[Pictures]]></category>
		<category><![CDATA[air conditioning]]></category>
		<category><![CDATA[centro]]></category>
		<category><![CDATA[chillers]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[deliveries]]></category>

		<guid isPermaLink="false">http://blog.gyron.net/?p=436</guid>
		<description><![CDATA[Related PostsCentro Suite 1 Phase 2 fit-out updateCentro update &#8211; Final air conditioning worksCentro update &#8211; HV transformer installation and chiller pipework connections]]></description>
			<content:encoded><![CDATA[<div id="attachment_437" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8013.jpg" rel="lightbox[436]"><img class="size-medium wp-image-437" title="Chillers arrive on-site with a Rig Lift" src="http://blog.gyron.net/wp-content/uploads/5d-img_8013-480x320.jpg" alt="Chillers arrive on-site with a Rig Lift" width="480" height="320" /></a><p class="wp-caption-text">Chillers arrive on-site with a Rig Lift</p></div>
<div id="attachment_438" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8021.jpg" rel="lightbox[436]"><img class="size-medium wp-image-438" title="Offloading first chiller on to the pre-prepared plinths" src="http://blog.gyron.net/wp-content/uploads/5d-img_8021-480x320.jpg" alt="Offloading first chiller on to the pre-prepared plinths" width="480" height="320" /></a><p class="wp-caption-text">Offloading first chiller on to the pre-prepared plinths</p></div>
<div id="attachment_439" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8028.jpg" rel="lightbox[436]"><img class="size-medium wp-image-439" title="Preparing to position the second chiller" src="http://blog.gyron.net/wp-content/uploads/5d-img_8028-480x320.jpg" alt="Preparing to position the second chiller" width="480" height="320" /></a><p class="wp-caption-text">Preparing to position the second chiller</p></div>
<div id="attachment_440" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_8046.jpg" rel="lightbox[436]"><img class="size-medium wp-image-440" title="Both chillers in place and ready for pipework connections" src="http://blog.gyron.net/wp-content/uploads/5d-img_8046-480x320.jpg" alt="Both chillers in place and ready for pipework connections" width="480" height="320" /></a><p class="wp-caption-text">Both chillers in place and ready for pipework connections</p></div>
<h3  class="related_post_title">Related Posts</h3><ul class="related_post"><li><a href="http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/" title="Centro Suite 1 Phase 2 fit-out update">Centro Suite 1 Phase 2 fit-out update</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-final-air-conditioning-works/" title="Centro update &#8211; Final air conditioning works">Centro update &#8211; Final air conditioning works</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-hv-transformer-installation-and-chiller-pipework-connections/" title="Centro update &#8211; HV transformer installation and chiller pipework connections">Centro update &#8211; HV transformer installation and chiller pipework connections</a></li></ul>]]></content:encoded>
			<wfw:commentRss>http://blog.gyron.net/pictures/centro-update-chillers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Centro update &#8211; Air conditioning pump installation</title>
		<link>http://blog.gyron.net/pictures/centro-update-air-conditioning-pump-installation/</link>
		<comments>http://blog.gyron.net/pictures/centro-update-air-conditioning-pump-installation/#comments</comments>
		<pubDate>Mon, 30 Mar 2009 17:37:47 +0000</pubDate>
		<dc:creator>Robin Balen - Gyron</dc:creator>
				<category><![CDATA[Centro fit-out]]></category>
		<category><![CDATA[Pictures]]></category>
		<category><![CDATA[air conditioning]]></category>
		<category><![CDATA[centro]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[pipework]]></category>
		<category><![CDATA[pumps]]></category>

		<guid isPermaLink="false">http://blog.gyron.net/?p=361</guid>
		<description><![CDATA[Related PostsCentro update &#8211; Final air conditioning worksCentro update &#8211; HV transformer installation and chiller pipework connectionsCentro update &#8211; Chillers]]></description>
			<content:encoded><![CDATA[<div id="attachment_362" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_7709.jpg" rel="lightbox[361]"><img class="size-medium wp-image-362" title="Inverter pumps arrive on-site" src="http://blog.gyron.net/wp-content/uploads/5d-img_7709-480x320.jpg" alt="Inverter pumps arrive on-site" width="480" height="320" /></a><p class="wp-caption-text">Inverter pumps arrive on-site</p></div>
<div id="attachment_363" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_7723.jpg" rel="lightbox[361]"><img class="size-medium wp-image-363" title="Preparing stands for pumps" src="http://blog.gyron.net/wp-content/uploads/5d-img_7723-480x320.jpg" alt="Preparing stands for pumps" width="480" height="320" /></a><p class="wp-caption-text">Preparing stands for pumps</p></div>
<div id="attachment_364" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_7743.jpg" rel="lightbox[361]"><img class="size-medium wp-image-364" title="Redundant inverter driven pumps ready for piperwork connections" src="http://blog.gyron.net/wp-content/uploads/5d-img_7743-480x320.jpg" alt="Redundant inverter driven pumps ready for piperwork connections" width="480" height="320" /></a><p class="wp-caption-text">Redundant inverter driven pumps ready for piperwork connections</p></div>
<div id="attachment_373" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/5d-img_7816.jpg" rel="lightbox[361]"><img class="size-medium wp-image-373" title="Starting work on pipework connections" src="http://blog.gyron.net/wp-content/uploads/5d-img_7816-480x320.jpg" alt="Starting work on pipework connections" width="480" height="320" /></a><p class="wp-caption-text">Starting work on pipework connections</p></div>
<h3  class="related_post_title">Related Posts</h3><ul class="related_post"><li><a href="http://blog.gyron.net/pictures/centro-update-final-air-conditioning-works/" title="Centro update &#8211; Final air conditioning works">Centro update &#8211; Final air conditioning works</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-hv-transformer-installation-and-chiller-pipework-connections/" title="Centro update &#8211; HV transformer installation and chiller pipework connections">Centro update &#8211; HV transformer installation and chiller pipework connections</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-chillers/" title="Centro update &#8211; Chillers">Centro update &#8211; Chillers</a></li></ul>]]></content:encoded>
			<wfw:commentRss>http://blog.gyron.net/pictures/centro-update-air-conditioning-pump-installation/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Centro update &#8211; Chiller and transformer bases</title>
		<link>http://blog.gyron.net/pictures/centro-update-chiller-and-transformer-bases/</link>
		<comments>http://blog.gyron.net/pictures/centro-update-chiller-and-transformer-bases/#comments</comments>
		<pubDate>Fri, 13 Mar 2009 17:19:38 +0000</pubDate>
		<dc:creator>Robin Balen - Gyron</dc:creator>
				<category><![CDATA[Centro fit-out]]></category>
		<category><![CDATA[Pictures]]></category>
		<category><![CDATA[centro]]></category>
		<category><![CDATA[chiller]]></category>
		<category><![CDATA[cooling]]></category>
		<category><![CDATA[HV]]></category>
		<category><![CDATA[power]]></category>
		<category><![CDATA[substation]]></category>
		<category><![CDATA[transformer]]></category>

		<guid isPermaLink="false">http://blog.gyron.net/?p=298</guid>
		<description><![CDATA[Related PostsCentro update &#8211; HV transformer installation and chiller pipework connectionsCentro Suite 1 Phase 2 fit-out updateCentro update &#8211; HV switchgear connections]]></description>
			<content:encoded><![CDATA[<div id="attachment_299" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/img_7485.jpg" rel="lightbox[298]"><img class="size-medium wp-image-299" title="Cutting chiller support pads in to rear plant yard" src="http://blog.gyron.net/wp-content/uploads/img_7485-480x320.jpg" alt="Cutting chiller support pads in to rear plant yard" width="480" height="320" /></a><p class="wp-caption-text">Cutting chiller support pads in to rear plant yard</p></div>
<div id="attachment_301" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/img_7546.jpg" rel="lightbox[298]"><img class="size-medium wp-image-301" title="Setting concrete bases for air conditioning chillers" src="http://blog.gyron.net/wp-content/uploads/img_7546-480x320.jpg" alt="Setting concrete bases for air conditioning chillers" width="480" height="320" /></a><p class="wp-caption-text">Setting concrete bases for air conditioning chillers</p></div>
<div id="attachment_303" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/img_7557.jpg" rel="lightbox[298]"><img class="size-medium wp-image-303" title="Concrete pads ready for chiller installation" src="http://blog.gyron.net/wp-content/uploads/img_7557-480x320.jpg" alt="Concrete pads ready for chiller installation" width="480" height="320" /></a><p class="wp-caption-text">Concrete pads ready for chiller installation</p></div>
<div id="attachment_300" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/img_7486.jpg" rel="lightbox[298]"><img class="size-medium wp-image-300" title="Preparing duct from substation to HV transformer" src="http://blog.gyron.net/wp-content/uploads/img_7486-480x320.jpg" alt="Preparing duct from substation to HV transformer" width="480" height="320" /></a><p class="wp-caption-text">Preparing duct from substation to HV transformer</p></div>
<div id="attachment_302" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/img_7554.jpg" rel="lightbox[298]"><img class="size-medium wp-image-302" title="HV transformer base formed and trenchwork prepared" src="http://blog.gyron.net/wp-content/uploads/img_7554-480x320.jpg" alt="HV transformer base formed and trenchwork prepared" width="480" height="320" /></a><p class="wp-caption-text">HV transformer base formed and trenchwork prepared</p></div>
<div id="attachment_304" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/img_7602.jpg" rel="lightbox[298]"><img class="size-medium wp-image-304" title="HV transformer base ready for installation with link to on-site substation" src="http://blog.gyron.net/wp-content/uploads/img_7602-480x319.jpg" alt="HV transformer base ready for installation with link to on-site substation" width="480" height="319" /></a><p class="wp-caption-text">HV transformer base ready for installation with link to on-site substation</p></div>
<h3  class="related_post_title">Related Posts</h3><ul class="related_post"><li><a href="http://blog.gyron.net/pictures/centro-update-hv-transformer-installation-and-chiller-pipework-connections/" title="Centro update &#8211; HV transformer installation and chiller pipework connections">Centro update &#8211; HV transformer installation and chiller pipework connections</a></li><li><a href="http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/" title="Centro Suite 1 Phase 2 fit-out update">Centro Suite 1 Phase 2 fit-out update</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-hv-switchgear-connections/" title="Centro update &#8211; HV switchgear connections">Centro update &#8211; HV switchgear connections</a></li></ul>]]></content:encoded>
			<wfw:commentRss>http://blog.gyron.net/pictures/centro-update-chiller-and-transformer-bases/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>CFD modelling for datacentres</title>
		<link>http://blog.gyron.net/green/cfd-modelling-for-datacentres/</link>
		<comments>http://blog.gyron.net/green/cfd-modelling-for-datacentres/#comments</comments>
		<pubDate>Thu, 09 Oct 2008 09:26:51 +0000</pubDate>
		<dc:creator>Robin Balen - Gyron</dc:creator>
				<category><![CDATA[Green Tech]]></category>
		<category><![CDATA[Pictures]]></category>
		<category><![CDATA[centro]]></category>
		<category><![CDATA[cfd]]></category>
		<category><![CDATA[cooling]]></category>

		<guid isPermaLink="false">http://blog.gyron.net/?p=114</guid>
		<description><![CDATA[There was an interesting post over at the Datacenter Knowledge blog a couple of days ago about the increasing use of Computational Fluid Dynamics within datacentres. I thought it would be useful to share some details on how we&#8217;re using this ourselves. Powering the cooling infrastructure within a datacentre is one of the largest components of the [...]]]></description>
			<content:encoded><![CDATA[<p>There was an interesting <a href="http://www.datacenterknowledge.com/archives/2008/10/07/cfd-thermal-modeling-whos-using-it-and-how/">post</a> over at the <a href="http://www.datacenterknowledge.com/">Datacenter Knowledge</a> blog a couple of days ago about the increasing use of <a href="http://en.wikipedia.org/wiki/Computational_fluid_dynamics">Computational Fluid Dynamics</a> within datacentres. I thought it would be useful to share some details on how we&#8217;re using this ourselves.</p>
<p>Powering the cooling infrastructure within a datacentre is one of the largest components of the operational expenditure related to running these facilities. As such, it&#8217;s been very important for us to fully understand the impact that various design options would have on our <a href="http://blog.gyron.net/news/teaser-trailer-for-new-centro-datacentre/">new Centro datacentre facility</a>.</p>
<div id="attachment_115" class="wp-caption aligncenter" style="width: 490px"><a href="http://blog.gyron.net/wp-content/uploads/cfd1.png" rel="lightbox[114]"><img class="size-medium wp-image-115 " title="CFD Model of various rack layouts within Gyron hosting suites" src="http://blog.gyron.net/wp-content/uploads/cfd1.png" alt="CFD Model of various rack layouts within Gyron hosting suite" width="480" height="307" /></a><p class="wp-caption-text">CFD Model of various rack layouts within Gyron hosting suites</p></div>
<p>The model above shows a horizontal temperature plane with a number of different rack layouts, cooling technologies, CRAC unit placements, and containment options. As you can see between the right and left hand sides, even very minor things like moving structural columns by a few centimeters can have big knock on effects&#8230; and in a lot of cases you can take some quite counter-intuitive steps to actually improve your cooling efficiciency (for example, installing baffles to slow down air flow through some sections of the hosting suites, removing some vented tiles, increasing the target set-point on the cooling management software etc).</p>
<p>In addition, now that we have a model of the facility in the CFD software, we can quickly and cost effectively plan out large customer deployments and verify that higher density rack loads will be cooled effectively before equipment is actually installed. We can even build these models in to our services on a contractual basis to give customers comfort that they will receive what we promise in the sales pitch, and when coupled with thermal imaging and enviromental monitoring built in to our infrastructure can form part of our Service Level Agreements.</p>
<h3  class="related_post_title">Related Posts</h3><ul class="related_post"><li><a href="http://blog.gyron.net/pictures/centro-phase-2-fit-out-update/" title="Centro Suite 1 Phase 2 fit-out update">Centro Suite 1 Phase 2 fit-out update</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-final-air-conditioning-works/" title="Centro update &#8211; Final air conditioning works">Centro update &#8211; Final air conditioning works</a></li><li><a href="http://blog.gyron.net/pictures/centro-update-hv-transformer-installation-and-chiller-pipework-connections/" title="Centro update &#8211; HV transformer installation and chiller pipework connections">Centro update &#8211; HV transformer installation and chiller pipework connections</a></li></ul>]]></content:encoded>
			<wfw:commentRss>http://blog.gyron.net/green/cfd-modelling-for-datacentres/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>